Hearth and Home Technologies 6000TRS-CE Indoor Fireplace User Manual


 
20
WARNING: THE REAR FLUE COLLAR SEAL
CAP MUST REMAIN ATTACHED TO THE
REAR FLUE COLLARS IF THE FLUE SYSTEM
IS ATTACHED TO THE TOP STARTING COL-
LARS. SEE FIGURE 15.
Figure 15
B. Installing Flue Components
After determining which set of starting collars will be
used (top or rear), follow venting instructions accordingly.
Venting Out the Rear Flue
Remove the installed rear seal cap from the rear
starting collars by cutting the strap at each end (See
Figure 15). Follow the flue configuration tables
accordingly.
Remove the 12.7cm diameter heat shield from the 1.27cm
diameter collar by sliding it out. Remove insulation piece.
WARNING: THE TOP HEAT SHIELD (INSIDE
THE FIREBOX) MUST REMAIN ATTACHED IF
THE FLUE SYSTEM IS ATTACHED TO THE REAR
STARTING COLLARS. SEE FIGURE 15.
Venting Out the Top Flue
Remove the top flue collar seal cap by cutting the strap
on each end. Remove both pieces of insulation inside
the top two starting collars (see Figure 15).
Remove the 10.2cm diameter heat shield from the 10.2cm
diameter collar by sliding it out.
You have to take the glass off again for positioning the
logs when the unit is finally installed in place and
finished around it. Reinstall the glass door. Attach flue
system to the top starting collars.
WARNING: FAILURE TO REMOVE INSULA-
TION IN THE SET OF COLLARS YOU
ARE
USING COULD CAUSE A FIRE.
WARNING: YOU MUST LEAVE THE INSULA-
TION IN PLACE IN THE SET OF COLLARS
YOU
ARE NOT USING.
!
!
!
!
Insert screwdriver
or similar object
here to remove cap.
CUT HERE
Venting
Out Rear
Venting
Out Top
HEAT
SHIELD
DISCARD
INSULATION
SEAL
CAP
SEAL
CAP
HEAT
SHIELD
INSULATION,
DISCARD
BOTH
PIECES