Harman Stove Company P61 Stove User Manual


 
4
Unpacking
The P61 is bolted to the skid to prevent movement
during shipping.
To free the stove from the skid you must remove the
hold-down bolts in the rear of the pedestal base.
Removing or Installing rear cover panels
To remove the rear cover panels, loosen the screws
slightly and slide the covers outward as shown in the
illustration. To reinstall, simply slide back into place and
retighten the screws.
Firebrick
Install the rebrick vertically on the angle above the
burnpot.
Flame Guide
Install the cast iron ame guide on top of the burnpot
and make sure it is fully seated against the auger
opening. The bottom of the ame guide is marked 38+.
Assembly and Installation
Rear Cover
Panels
Shipping Bolts: These
holes are also used for
Mobile Home Installation
Fig. 2
Draft Test Procedure
Before attaching any vent pipe to the stove, perform
a draft test, for later comparison.
Remove the plug bolt on the underside of the rebox
as shown. Using the hole from the bolt, attach a draft
meter that is capable of reading at least .5 inches of
water column (W.C.). You are going to want the meter
reading negative pressure.
Turn the feed adjuster to "Test". For the rst minute,
everything will run. Record the high draft reading
_______ . After the rst minute, the distribution blower
will go to a low speed. Then, after the second minute,
two minutes after turning to test, the distribution
blower will come back up to high, and the combustion
blower will drop to low. During this time, record the low
draft________. Perform the test again after the venting
is complete. Compare your readings. If there is more
than a .05 difference, you have too much restriction in
the venting. There is no adjustment for the draft other
than improving the venting conguration. Leaving the
stove in "test" will continue to cycle the blowers each
minute. Record your nal draft redings here. _________
High, and ________ Low.