Harman Stove Company P61 Stove User Manual


 
14
Feed adjuster
Sets the maximum feed
rate
Test
Runs all motors at full
speed for two minutes
to check operation. After
two minutes the stove
will go to minimum burn
and the blowers will
alternate from high to
low every two minutes
to remind you that you
are still in "Test Mode".
Distribution Blower
speed adjustment range.
STATUS LIGHT ERROR MESSAGES:
1 Blink: Indicates control board self diagnostic failure.
This requires a manual reset*.
3 Blinks: Indicates ESP (Exhaust Sensing Probe)
failure. This requires a manual reset*.
4 Blinks: Can occur only in Room Temp Mode and
indicates Room Sensing Probe failed or not installed.
If a Room Sensing Probe is then installed the status
light will automatically reset.
6 Blinks : Indicates that the control has calculated poor
or incomplete combustion occurring for more than 50
minutes. See Troubleshooting section for more details.
* Manual reset, disconnect power cord for a few
seconds and reconnect. If error still occurs call your
Dealer.
Temp dial
Allows you to adjust the Room temperature in Room Temp Mode
using the outer scale marked in degrees Fahrenheit. It also allows
you to adjust the stove temperature while in Stove Temp Mode
using the inner scale marked from 1 to 7.
Mode Selector
Allows you to choose between Room Temp Mode,
Stove Temp Mode, or OFF. Also allows you to vary
the distribution blower speed by turning the knob to
the high or low side of each mode.
Power Light
Indicates power to the
control.
Indicates Power to the
feed motor.
Indicates Power to
combustion blower
Status Light
Will be lit in either stove
or room temp mode when
pointer is not within off
position band except after
normal shut down. Blinks
to indicate errors listed
below.
Indicates power to
distribution blower.
ESP CONTROL