3
The Advance pellet stove is more than just automatic ignition, it is also automatic temperature
control. The automatic system will allow the fire size to be adjusted to match the heating
needs and even put the fire out if necessary. If heat is needed after the fire is out, the
Advance will automatically re-ignite and adjust the fire size to match the heating need. The
totally automatic room sensor mode is recommended because of its efficiency.
The unit can be switched between "AUTO" and "MANUAL" at any time during operation.
Automatic Ignition/Operation
Room Temperature Mode: This setting will produce a room
temperature of 70 degrees with the distribution blower at
medium speed.
This setting will produce medium heat with the
distribution blower on "low".
This setting will produce continuous maximum heat
output with the distribution blower at full speed.
Stove Temperature Mode
Igniter switch to "AUTO"
Room Temperature Mode
In "Room Temp Mode" heat output is controlled au-
tomatically by the Room Sensing Probe. When the Room
Sensing Probe calls for heat, the stove will increase out-
put. When the Room Sensing Probe is getting close to
the set temperature, the stove will begin to level off out-
put and keep the fire burning at just the right temperature
to maintain that setting.
High output is determined by the feed rate set-
ting. This setting, generally on #4, can be increased if
higher burn rates are necessary. The unit's maximum
burn rate should not create less than 1" of ash on the
burn pot front edge. See Fig.2, Page 4. Overfeeding is
not a safety concern, but fuel may be wasted if unburned
pellets fall into the ash pan.
In "Room Temp Mode" a constant fuel consumption
rate is sacrificed for exact room temperature. Therefore,
as it gets colder more pellets will be burned automati-
cally.
The distribution blower speed will vary according to
the position of the mode selector pointer, and fire size.
Igniter switch to "AUTO"
Stove Temperature Mod
e
This allows for automatic ignition upon start-up only.
The unit can then be set at any desired setting. The heat
output and fuel consumption will remain constant regard-
less of room temperature. The unit's maximum feed rate
should not create less than 1" of ash on the burn pot front
adge. See Fig 2, Page 4.
The unit's low burn or maintenance setting is as
low as it will go. It will not go out unless it runs out of
fuel or is turned off.
Shut-Down Procedure
To kill the fire or stop burning the stove, turn the Mode Selector to
"OFF". This will cause the fire to diminish and burn out. When the fire burns
out and the stove cools down everything will stop.
If you pull the plug to shut down the stove, all motors will stop. This
may cause incomplete combustion and smoke in the firebox. If the load door
is opened the smoke may escape.
The best way to shut down the stove is simply let it run out of pellets,
then the stove will shut down automatically.
Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.