Harman Stove Company Advance Pellet Stove Stove User Manual


 
15
#5 Installing into an existing fireplace
chimney ( US and Canada)
This method provides excellent venting for nor-
mal operation. This method also provides natural draft
in the event of a power failure.
In Canada and some places in the US it is re-
quired that the vent pipe extend all the way to the top
of the chimney.
In this method a cap should also be installed on
the chimney to keep out rain. Be sure to use approved
pellet vent pipe fittings. Seal pipe joints with silicone in
addition to the sealing system used by the manufac-
turer. Pipe size should be increased to 4" using this
method.
#6 Installing into an existing
chimney ( US and Canada )
This method provides excellent venting for nor-
mal operation. This method also provides natural
draft in the event of a power failure.
In Canada and some places in the US it is re-
quired that the vent pipe extend all the way to the top
of the chimney. The pipe or liner inside the chimney
should be 4"diameter.
In this method a cap should also be installed
on the chimney to keep out rain.
Fig.24
Fig.25
Venting