8
With the module installed and secured, reach through
the side access ports and plug in the electrical connections.
(Two AMP Mate-N-Lok connectors).
Install the Back Log and Back Brick Panel
These two components are installed as a single piece.
Rest the back brick panel on the shelf located on the back
side of the back log, and center it. Holding the two pieces as
a single unit, tilt the top forward slightly and manuever it
over the top of the rear burner—taking care that the top
corners clear the front opening. Place it snugly against the
back wall and center it.
Install the Side Brick Panels
These slide into place along each side and are held by
friction. The notch in each panel faces the back. Install one
side, and then the other.
Install the Ember Strips
The ember strips rest against the front of the firebox
and should fit snugly. Guide them toward you and to the
outside until they fit snugly. Check the air slot in the inside of
the ember strips to confirm that they do not obstruct it.
Install the Center Log
The center log goes all the way to the back and should
be centered. When properly positioned, there should be an
even gap along the front of the center burner in the cavity in
the log. A small portion of the log support frame will be
revealed.
The center log has a round viewing port in the left end
through which the pilot can be observed.
Install the Branch
Orient the branch with the forked end toward the left
rear of the stove and slip it over the two locator pins, one on
top of the back log and the other on the top of the center log.
Secure the Glass Front
NOTE: The glass front is heavy. Lift it carefully to pre-
vent damage. Center the glass on the opening and suspend
it in place by placing the the tab hooks over the top edge of
the opening. Loosen the wing nuts that hold the spring-loaded
levers in place. Press the glass slightly against the stove to
confirm that it seats properly, then press it firmly against the
front while pulling the levers forward to engage them. Tighten
the wing nuts.
The complete log set with all logs in the correct position.
The two electrical
connectors may be
reached through the
side access port
ASSEMBLY