Harman Stove Company 929 DV Stove User Manual


 
20
Converting the Clarity Direct Vent
from One Gas to Another in the Field
NOTE: THE CONVERSION SHALL BE CAR-
RIED OUT IN ACCORDANCE WITH THE RE-
QUIREMENTS OF THE PROVINCIAL OR LOCAL
AUTHORITIES HAVING JURISDICTION AND IN
ACCORDANCE WITH REQUIREMENTS OF THE
CURRENT EDITION OF THE NATIONAL FUEL
GAS CODE, ANSI Z223.1 or the CAN/CGA-B149 IN-
STALLATION CODES.
Conversion Kit Components
• Burner system module
• Conversion label
The Clarity is designed to burn either natural gas or
propane, but requires a dedicated burner system module for
either fuel. Conversion to the alternate fuel is a simple mat-
ter of replacing one burner system module with another. A
label on the burner system module will specify for which
fuel it is intended.
To accomplish the conversion procedure, follow these
steps.
1. Unplug the Cordset
2. Remove the Glass Front
Push open the wing door on each side of the unit. Loosen
the wing nut on each of the two spring-loaded levers. Grasp
each lever and push to the rear to disengage the front. To
keep the levers in the disengaged position, tighten the wing
nuts. Lift the glass front slightly and remove it from the
stove.
3. Remove the Log Set
See the directions on page 14.
4. Unplug the Electrical Connectors
Reach through the side access port and unplug the
two multi-pin connectors and the white lead from the fan.
5. Remove from the theaded studs the two wing nuts
that secure the module from underneath, one on each
side.
6. Remove the Existing Burner System Module
The burner system module may be removed as an inte-
grated unit, and it may help to have an assistant who can
help guide the components into position.
Tilt and rotate the module as needed to remove it.
Once the existing module has been removed, follow the
instructions on page 7 for installing the replacement module,
re-connecting the wiring, re-installing the logs, and securing
the glass front.
After completing the fuel conversion, an installer fuel la-
bel—supplied with the burner system module—must be filled
out by the installer and attached to the inside of the wing
door near the rating plate. Cover the original fuel label with
the new label.
SEE WIRING DIAGRAM ON PAGE 15.
The above label on the
Clarity's burner system
module indicates that the unit
is equipped to burn natural
gas.
The above label on the
Clarity's burner system
module indicates that the unit
is equipped to burn propane.
APPENDIX A
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING ERRORS CAN
CAUSE IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.
Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.