Clearances
The following clearances to combustibles must be ob-
served:
Heater to left sidewall 9" (230 mm)
Heater to right sidewall 9" (230 mm)
Heater corner to walls 4" (100 mm)
Heater to back wall 3" (75 mm)
(measured from rear of heater to wall)
Heater to alcove ceiling 18" (460 mm)
Maximum alcove depth 14" (355 mm)
In addition to the clearances mentioned previously, ad-
equate accessibility clearance for servicing and proper op-
eration must be maintained.
If this appliance is installed directly on carpeting, vinyl
tile, or other combustible material other than wood flooring
the appliance shall be installed on a metal or wood panel
extending at least the full width and depth of the appliance.
Clearance to back wall
Sidewall clearance
3" (75 mm)
9" (230 mm) 9" (230 mm)
IMPORTANT NOTICE
Due to high temperatures, the Clarity Direct Vent
Gas Heater should be located out of traffic and away
from furniture and draperies.
Children and adults should be alerted to the haz-
ards of high surface temperatures and should stay
away to avoid burns or clothing ignition.
Young children should be carefully supervised
when they are in the same room as the appliance.
Clothing or other flammable materials should not
be placed on or near the Clarity Direct Vent Gas Heater.
18" (460 mm)
Clearance to alcove ceiling.
14" (355 mm)
Maximum alcove depth
Clearance from corner of unit to walls.
4" (100 mm)
4" (100 mm)