Hampton Direct HI200 Indoor Fireplace User Manual


 
HI200 Hampton Wood Cast Insert4
SAFETY LABEL
This is a copy of the label that accompanies each
HI200 Wood Insert. We have printed a copy of
the contents here for your review.
COMPONENTS REQUIRED FOR INSTALLATION: 6IN / 150MM STAINLESS STEEL LINER. STANDARD ADAPTOR (171-932) OR OFFSET
ADAPTOR (171-936), FAN (210-911 or 210-915), ELECTRICAL RATING: VOLTS 115, 60 HZ, 0.6 AMPS
OPTIONAL COMPONENT: SCREEN DOOR (846-101)
DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE
FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. OPERATE WITH FEED DOOR CLOSED, OPEN TO FEED FIRE ONLY. REPLACE GLASS ONLY
WITH CERAMIC GLASS (5MM). INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP
MAY OCCUR RAPIDLY. DO NOT OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING.
MANUFACTURED BY:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC V4G 1H4
HOT WHILE IN OPERATION
DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY.
CONTACT MAY CAUSE SKIN BURNS.
READ ABOVE INSTRUCTIONS.
CAUTION
UNITED STATES ENVIRONMENTAL PROTECTION
AGENCY CERTIFIED TO COMPLY WITH JULY 1990,
PARTICULATE EMISSION STANDARDS.
JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC
2008 2009 2010
(Duplicate
Serial #)
MADE IN CANADA
339
DATE OF
MANUFACTURE
NOTE: Hampton units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
LISTED FACTORY BUILT FIREPLACE INSERT
CERTIFIED FOR USE IN CANADA AND U.S.A.
MODEL: HI200
TESTED TO:
ULC S628-M93 / UL 1482-1998 / ULC S627-00 / UL 737-2000 REPORT NO. 632-3198 (SEPT.1993)
DO NOT REMOVE THIS LABEL
339
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (MEASURED FROM INSERT BODY)
INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 1.5IN / 38MM
ABOVE AN ADJACENT COMBUSTIBLE FLOOR. COMBUSTIBLE FLOOR MUST
BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING
(E) 16 IN / 405MM (US), 18 IN / 457MM (CAN) TO FRONT AND (G) 8 IN / 205MM
TO SIDES FROM FUEL DOOR.
918-740
ADJACENT SIDEWALL A) 15in / 380mm
MANTLE B) 20in / 510mm
TOP FACING C 14in / 355 mm
SIDE FACING D) 7.375in / 185mm
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS. INSTALL AND USE ONLY
IN MASONRY FIREPLACE OR FACTORY BUILT FIREPLACE.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.