Hampton Direct HI200 Indoor Fireplace User Manual


 
HI200 Hampton Wood Cast Insert14
BRICK FLUE BAFFLE &
SECONDARY AIR TUBE
INSTALLATION
The ue baf e system located in the upper area
of the rebox is removable to make cleaning
your chimney system easier. The brick baf es
must be installed prior to your rst re. Smoke
spillage and draft problems may occur if the
baf es are improperly positioned. Check the
position of the brick baf es on a regular basis as
they can be dislodged if too much fuel is forced
into the rebox.
FIREBRICK ASSEMBLY
Firebrick is included to extend the life of your
insert and radiate heat more evenly. Check to
see that all rebricks are in their correct posi-
tions and have not become misaligned during
shipping.
Side View
Front View
Front View
DRAFT CONTROL
Before establishing your rst re, it is important
that you fully understand the operation of draft
control. The draft control rod is on the left side
of the Insert and it controls the intensity of the
re by increasing or decreasing the amount
of air allowed into the rebox. To increase the
draft, slide the rod to the left and to decrease
the draft, slide the rod to the right.
1) If the two air tubes are installed continue
on to Step 2), if not, follow the instructions
below. Install the air tube into the holes in the
side channels. The notch goes on the right
hand side with the air holes facing toward
the door. Slide the tube into the left hand
side, as far as possible and then bring it back
into the hole on the right hand side until it
locks into position. If the tube will not slide
in easily simply use a pair of vise grips or
pliers and tap it into place with a hammer. A
tighter t will ensure the tube will not move
when the unit is burning.
2) Slide the left baf e brick over the front air
tube and then slide it back over the rear air
tube.
3) Tilt the left baf e brick up on top of the side
channel and it will leave enough room to
position the right baf e brick in the same
manner as Step 1) above. Then reposition
the left baf e brick at on the air tube.
4) Important: push both baf e bricks so
they are tight against the side walls and
to the back.
Note: When getting the chimney cleaned,
remove the baf e bricks for access
to the ue, then replace them when
cleaning is completed.
As well as a primary and glass wash air system,
the unit has a full secondary draft system that
allows air to the induction ports at the top of the
rebox, just below the ue baf e.
WARNING: To build a re in ignorance or to
disregard the informa tion contained in this
section can cause serious permanent dam-
age to the unit and void your warranty.
INSTALLATION
Slide Left to
Increase Draft
Slide Right to
Decrease Draft