Guardian Technologies ACT1000 Door User Manual


 
ACT1000/2000 Operating Instructions Software Version 3.23-00
Page 7 of 32
Display Log
The Display Log function allows the operator to view events in the historical log directly on
the LCD display. When this option is selected, the latest event in the log is displayed with the
time and date on the top line of the display, and the event details being scrolled across the
bottom line. Each log event will be displayed in turn (stepping backwards in time) until the
end of the log is reached. Pressing the 0 key advances immediately to the previous event
without waiting for it to be displayed. Pressing the
key locks the current event on the
display until
is pressed again. Pressing the
key exits from the display log function.
Print Log
The Print Log function allows the user to request the immediate printing of the entire system
log on an attached serial printer. If real-time log printing is enabled, new events will be
buffered until the complete log print is completed. Note that selection of this function only
starts the log printing, and this may take a few minutes to complete. The display will indicate
that printing has commenced, and return to the previous menu. If this function is re-selected
before the log has been completely printed, then the option to stop the printout is given.
ACT Recommend the Epson LQ-300:
Wiring between Printer & Controller: Controller Printer
0v TX RX SERIAL (25 way connector)
0V---------------------- PIN 7
TX---------------------- PIN 3
RX---------------------- PIN 20
Printer settings:
CHARACTER TABLE PC850
PAGE LENGTH OF TRACTOR 11 INCHES
SKIP OVER PERFORATION OFF
AUTO TEAR OFF OFF
GRAPHIC PRINT DIRECTION BI-D
SOFTWARE ESC/P2
AGM OFF
AUTO LINE FEED OFF
INTERFACE SERIAL
BIT RATE 9600BPS
PARITY BIT NONE
DATA LENGTH 8 BITS
EXT/ACK OFF
STATE REPLY OFF
Filter Log (ACT 2000 Only)
The Filter Log function allows the user to prevent certain events from being entered on the
system log. Normally all events are logged, but to prevent ACTWinPro from having to store a
lot of information on a large installation, some events may be filtered out.
The event types that can be filtered are access granted, access denied, alarms (mains fail,
tamper etc.), door events (exit button pressed etc.) and others. The 0 key advances to each
event type, and the
key enables or disables the displayed event type.
The events may also be filtered out on certain doors. Normally all doors are allowed, but the
user may prevent certain doors from reporting events.