G0637/G0638 Cyclone Dust Collector
-19-
Intake Cylinder and Blower Housing
1. Place the intake cylinder on the floor and
apply the 3 x 6 x 1800mm gasket to the
intake cylinder top rim, between the mounting
holes and the inside edge (see
Figure 15).
3. Use the (4)
5
⁄16"-18 x
3
⁄4" hex bolts and (4)
5
⁄16"
flat washers to secure the intake cylinder to
the bottom of the blower housing (see
Figure
16).
Note: Because the mounting bolts for the
intake cylinder are not accessible after
assembly is complete, consider using medium
strength (red) Loctite
©
Threadlocker (Grizzly
Model H2509 or H2515) to ensure the fas
-
teners will not come loose with operational
vibration.
When using power lifting equipment dur-
ing the assembly, make sure the equipment
is safe, fully operational, and adequately
rated for the weight being lifted. The opera
-
tor of the equipment must be experienced
and able to use safe methods during these
processes. Failure to heed these warnings
could result in serious personal injury or
death.
Figure 15. Gasket applied to the intake cylinder
rim.
Gasket
Figure 16. Intake cylinder mounted to blower
housing.
2. With assistance and the power lifting equip-
ment, keep the intake cylinder on the floor
and lower the blower housing over the top of
the intake cylinder.
Intake Barrel and Large Cyclone
Funnel
1. Position the large cyclone funnel so the small
end rests on the floor.
2. Apply the 3 x 6 x 2500mm gasket to the top
mating surface of the large cyclone funnel.
3. Take note that the large cyclone funnel top
and the intake barrel mating surfaces have
four places around the rims where there are
three mounting holes close together.