Max Model Setup
36 332305B
1. To set the OFF Time use the
UP or DOWN ARROW button
to scroll through numerals 0
to 9 until the desired number
appears in the first HH (hour)
field.
2. Press the ENTER button to lock in the
selection. The next HH number field to
the right flashes indicating it is ready for
programming.
3. Use the UP or DOWN
ARROW button to scroll
through numerals 0 to 9 until
the desired number appears
in the second HH number
field.
4. Press the ENTER button to lock in the
selection.
The next number field to the right
flashes and the LED lights under MM; indicating it is
ready to program the minutes fields.
5. Repeat steps 1 - 4 to set the next MM (minutes)
fields.
6. After pressing the ENTER button to set
the last MM field, the OFF Time informa-
tion is saved.
Prelube
The Prelube function determines operation of the pump
when power is applied. It can be set to OFF or ON.
OFF (default) - The unit resumes its lubrication cycle at
the point it was at when power was removed.
ON - The unit begins a pump cycle.
Setting Prelube
1. After you set the OFF Time information and press
the ENTER button, the G3 automatically switches to
the Prelube Delay setup.
Notice the LED next to the prelube
icon on the G3 display lights indicat-
ing you are now in the Prelube setup
mode.
2. OFF displays. If you
want the prelube
cycle to begin imme-
diately, leave this set
to OFF.
3. Press the ENTER button to set the
selection.
4. If you want to set a
prelube delay time,
press the DOWN
ARROW button to
change OFF to ON
on the display.
Prelube Delay
Prelube Delay can be entered to delay the start of the
pump’s cycle on power up. If prelube is set to ON, a pre-
lube delay time in MM:SS must be entered. By default,
the delay is set to 0 (begin an ON cycle immediately).
Delaying the prelube function may be desired if other
critical functions or systems of your machine or vehicle
are also coming on line during power up.
1. Prelube Delay is set in
MM:SS (minutes and sec-
onds). To set the time use the
UP or DOWN ARROW button
to scroll through numerals 0
to 5 until the desired number
appears in the first MM (minutes) field.
The maximum length of time Prelube Delay can be
set to is 59:59 (59 minutes:59 seconds).
2. Press the ENTER button to lock in the
selection. The next MM number field to
the right flashes indicating it is ready for
programming.
3. Use the UP or DOWN
ARROW button to scroll
through numerals 0 to 9 until
the desired number appears
in the second MM number
field.
4. Press the ENTER button to lock in the
selection.
The next number field to the right