Technical Data
72 332305B
Technical Data
A
Maximum Working Pressure 5100 psi (35.1 MPa, 351.6 bar)
Power
100-240 VAC 88 - 264 VAC; 0.8 A current, 90 VA Power, 47/63 Hz,
Single phase, inrush/locked rotor, max 40A (1ms)
12 VDC 9 - 16 VDC; 5 A current, 60 W, inrush/locked rotor 12 A
24 VDC 18 - 32 VDC; 2.5 A current, 60 W, inrush/locked rotor 6 A
Outputs - Alarm Relay
Rated Load Resistive: 0.4 A at 125 VAC, 2 A at 30 VDC
Inductive: 0.2 A at 125 VAC, 1 A at 30 VDC
Max Operation Voltage Resistive: 250 VAC, 220 VAC
Inductive: 250 VAC, 220 VDC
Max Operating Current Resistive: 3 A (AC), 3A (DC)
Inductive: 1.5 A (AC), 1.5 A (DC)
Max Switching Capacity Resistive: 50 VA, 60 W
Inductive: 25 VA, 30 W
Min Permissible Load
Resistive: 10
µA, 10m VDC
Inductive: 10
µA, 10m VDC
Outputs - Vent Valve
Required Vent Valve Type Normally closed
Output Voltage
100/240 VAC 24 VDC
12 VDC Input Voltage
24 VDC Input Voltage
Max Operating Current 2 A
Max Operating Power 48 W
Inputs - Cycle Pressure, 1, 2, 3, Machine Count
Required Switch Type Normally open (sink, source, or dry contact)
Sensor Voltage
100/240 VAC 24 VDC
12 VDC Input Voltage
24 VDC Input Voltage
Load Current
100/240 VAC 22mA @ 24 VDC
12 VDC 11mA @ 12 VDC
24 VDC 22mA @ 24 VDC
Maximum Residual Voltage
100/240 VAC 4 V
12 VDC 2 V
24 VDC 4 V
Maximum Off Current
100/240 VAC 1.5 mA
12 VDC 1 mA
24 VDC 1.5 mA
Input Impedance 1.1 K
Response Time 60 ms
Cycle Rate 8.0 Hz (50% duty cycle)