Run Mode
52 332305B
Lubrication Mode (Pump ON) Controls
In Max models the Lubrication Mode (Pump ON) can be
controlled by either cycle and/or pressure sensors.
If cycle and/or pressure controls have been set to some-
thing other than OFF the display will alternate between
cycles (C1, C2, C3) and/or active sensors (P1, P2, P3)
and Backup Time.
If cycle or pressure controls have been set to OFF then
the Lubrication Mode (Pump ON) will be controlled by
On Time (see Time Control, page 51).
With cycle and/or pressure controls set, the lubrication
cycle (Pump ON) is ended by meeting all required cycle
and/or pressure settings.
Cycle Control
• A set number of triggered counts in a cycle
based system (C1). Typically a proximity switch
connected to a divider valve.
• The LED next to the appropriate sensor (C/P1,
C/P2, C/P3) illuminates.
• The display indicates the sensor (C1, C2, C3)
and the remaining cycles for that sensor (F
IG.
30).
The example shown in F
IG. 30 shows sensor C1
with 5 cycles remaining.
Pressure Control
• A single triggered count in a pressure based
system (P1). Typically a pressure switch on the
end of a line of injectors.
• The LED next to the appropriate sensor (C/P1,
C/P2, C/P3) illuminates (F
IG. 31 and FIG. 32).
• The display indicates the sensor (P1, P2, P3)
and whether the pressure switch for that sensor
has been triggered or not.
- 01 = pressure switch has not been triggered
- 00 = pressure switch is triggered.
The example shown in F
IG. 31 shows sensor P1
with a pressure switch that has been triggered.
F
IG. 32 (page 53) shows sensor P2 with a pres-
sure switch that has NOT been triggered.
F
IG. 30
ON
OFF
!
1 23
HH MM
SS ##
MM : SS HH : MM
2
3
1
P
C
C
P
C
P
C
P
FIG. 31
ON
OFF
!
1 23
HH MM
SS ##
MM : SS HH : MM
2
3
1
P
C
C
P
C
P
C
P