Graco 308981ZAD Septic System User Manual


 
35308981
Husky 515 and 716 Performance Charts
0
5
10
15
20
25
30
0246810121416
(7.6) (15.2) (22.7) (30.3) (37.9) (45.4) (53.0) (60.6)
Air Consumption
Test Conditions: Pump tested in water with inlet submerged.
FLUID FLOW––gpm (lpm)
A
B
C
To find Pump Air Consumption (scfm or m#/min) at a
specific fluid flow (gpm/lpm) and air pressure
(psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Read vertical line up to intersection with selected air
consumption curve.
3. Follow left to scale to read air consumption.
AIR CONSUMPTION––scfm (cubic meters/min)
Air Consumption Curves
A at 100 psi (0.7 MPa, 7 bar) air pressure
B at 70 psi (0.48 MPa, 4.8 bar) air pressure
C at 40 psi (0.28 MPa, 2.8 bar) air pressure
(0.28)
(0.14)
(0.42)
(0.56)
(0.70)
(0.84)