Graco 308981ZAD Septic System User Manual


 
21308981
Service
Diaphragms (Husky 716)
Fig. 10
11
} Included in Fluid Section Repair Kit D05XXX
1
2
Torque to 35 to 45 in-lb (4.0 to 5.1 N-m).
Apply grease.
The words “AIR SIDE” on diaphragms (and on backup diaphragms used
on PTFE models) must face toward diaphragm shaft (15).
3
4
Install with lips facing out of center housing (11).
Flat side of the air-side diaphragm plate must face
toward diaphragm shaft (15).
5
Apply medium-strength (blue) LoctiteR or equivalent
to threads, and torque to 80 to 90 in-lb (9 to 10 N-m) at
100 rpm maximum.
6
7
101
102
102
105
105
}401
}402 6
140
}115
}416
1
3
109
141
2
4
4
5
6
Torque to 80 to 90 in-lb (9 to 10 N-m). See
Torque Sequence, page 29.
7
7
136
12}
4
3
416}
1
9072A
13
133
15
3
5
6
}401
4
HD Overmolded Diaphragm
6