Goodman Mfg GMV95/GCV9 Furnace User Manual


 
SS-GMV95 www.goodmanmfg.com 9
PRODUCT SPECIFICATIONS
GCV9 COOLING SPEEDS
GCV90704CXA
Cooling
Speed
Tap
Adjust
Tap
CFM at .1” to .8” w.c. ESP
Low Stage
High/Single-
Stage
A
Minus (-) 378* 540
Normal 390 600
Plus(+) 429 660
B
Minus (-) 468 720
Normal 520 800
Plus(+) 572 880
C
Minus (-) 644 990
Normal 715 1,100
Plus(+) 787 1,210
D
Minus (-) 836 1,286
Normal 929 1,429
Plus(+) 1,022 1,572
GCV90905DXA
Cooling
Speed
Tap
Adjust
Tap
CFM at .1” to .8” w.c. ESP
Low Stage
High/Single-
Stage
A
Minus (-) 513* 720
Normal 520 800
Plus(+) 572 880
B
Minus (-) 644 990
Normal 715 1,100
Plus(+) 787 1,210
C
Minus (-) 819 1,260
Normal 910 1,400
Plus(+) 1,001 1,540
D
Minus (-) 1,053 1,620
Normal 1,170 1,800
Plus(+) 1,287 1,980
GCV91155DXA
Cooling
Speed
Tap
Adjust
Tap
CFM at .1” to .8” w.c. ESP
Low Stage
High/Single-
Stage
A
Minus (-) 500* 705
Normal 508 783
Plus(+) 559 861
B
Minus (-) 621 982
Normal 690 1,091
Plus(+) 759 1,200
C
Minus (-) 815 1,265
Normal 906 1,406
Plus(+) 997 1,547
D
Minus (-) 1,049 1,628
Normal 1,165 1,809
Plus(+) 1,282 1,990
HIGH- /SINGLE-STAGE & LOW-STAGE COOLING SPEEDS
Notes:
These charts are for furnaces installed at 0 - 2000 feet. At higher altitudes, a properly derated unit will have the same temperature rise at a
particular CFM, while the ESP at that CFM will be lower.
The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate.
Do not operate above .5” w.c. ESP in heating mode.
Propane gas installations will have a High Stage rise approximately 4° lower than shown in above table.
* Motor CFM maximum
* Motor CFM maximum
* Motor CFM maximum