Goodman Mfg GMV95/GCV9 Furnace User Manual


 
SS-GMV95 www.goodmanmfg.com 3
PRODUCT SPECIFICATIONS
SPECIFICATIONS
GMV95
0453BXB
GMV95
0704CXB
GMV95
0905DXB
GMV95-
1155DXB
GCV9
0704CXB
GCV9
0905DXB
GCV9
1155DXA
Heating Capacity
High Fire Input¹ 46,000 69,000 92,000 115,000 69,000 92,000 115,000
High Fire Output¹ 45,000 67,000 90,000 109,000 65,000 87,000 109,000
Low Fire Input¹ 32,000 48,000 64,000 80,000 48,000 64,000 80,000
Low Fire Output¹ 30,800 46,400 61,700 77,400 45,000 60,100 77,400
AFUE² 95 95 95 95 93 93 93
Tons AC @ 0.5” ESP 1.5 - 3.0 1.5 - 4.0 2.0 - 5.0 2.0 - 5.0 1.5 - 4.0 2.0 - 5.0 2.0 - 5.0
Temperature Rise Range (°F) 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60 40-70
Circulator Blower
Size (D x W) 10” X 7” 10” X 10” 11” X 10” 11” X 10” 10” x 10” 11” X 10” 11” X 10”
Horespower @ 1750 RPM ½ ¾ 1 1 ¾ 1 1
Speed Variable Variable
Vent Diameter³ 2” 2” 3” 3” 2” 3” 3”
No. of Burners 2 3 4 5 3 4 5
Filter Size (in²)
Disposable 288 384 480 486 384 480 486
Permanent 576 768 960 972 768 960 972
Electrical Data
Min. Circuit Ampacity (amps)
4
10.4 12.8 14.6 14.6 12.8 14.6 14.6
Max. Overcurrent Protection
5
15 amps 15 amps 15 amps 15 amps 15 amps 15 amps 15 amps
Ship Weight (lbs) 133 135 172 175 135 172 175
1– Natural Gas BTU/h
2– DOE AFUE based upon Isolated Combustion System (ICS)
3– Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the  ue outlet (required). Vent pipe must
be either 2” or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The
optional Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.
4– Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with
National Electrical Codes. Extensive wire runs will require larger wire sizes.
5– Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type
circuit breakers of the same size as noted.
Notes:
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
Gas Service Connection ½” FPT
Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code
and/or all existing local codes.