10 www.goodmanmfg.com SS-GMV95
PRODUCT SPECIFICATIONS
COOLING-BASED CONTINUOUS FAN SPEEDS
GCV90704CXA GCV90905DXA GCV91155DXA
Cooling
Speed Tap
Adjust
Tap
Continuous
Fan Speed
CFM
Cooling
Speed Tap
Adjust Tap
Continuous
Fan Speed
CFM
Cooling
Speed Tap
Adjust Tap
Continuous
Fan Speed
CFM
A
Minus (-) 380*
A
Minus (-) 513*
A
Minus (-) 500*
Normal 380* Normal 513* Normal 500*
Plus(+) 380* Plus(+) 513* Plus(+) 500*
B
Minus (-) 403
B
Minus (-) 554
B
Minus (-) 550
Normal 448 Normal 616 Normal 611
Plus(+) 493 Plus(+) 678 Plus(+) 672
C
Minus (-) 554
C
Minus (-) 706
C
Minus (-) 709
Normal 616 Normal 784 Normal 787
Plus(+) 678 Plus(+) 862 Plus(+) 866
D
Minus (-) 720
D
Minus (-) 907
D
Minus (-) 912
Normal 800 Normal 1,008 Normal 1,013
Plus(+) 880 Plus(+) 1,109 Plus(+) 1,114
GCV9 COOLING SPEEDS (CONT.)
* Motor CFM maximum
During Auto-Comfort mode, the furnace ramps up to 50% of the demand for half a minute. It then
ramps to 82% of the full cooling demand air ow and operates there for approximately 7½ minutes.
The motor then steps up to the full demand air ow. This mode spends a half minute at 50% air ow
OFF delay.
AUTO-COMFORT MODE
STANDARD ALTITUDE INSTALLATIONS
Gas Altitude Kit Ori ce
Manifold Pressure
Pressure Switch
Change
High Stage Low Stage
Natural 0-7000 Changeover None #43 3.5” W.C. 1.9” W.C. None
Propane 0-7000 LPM-03B & LPM-05 #55 10.0: W.C. 6.0” W.C. None
For installation in Canada, gas furnaces are certi ed only to 4,500 ft.
For GCVA installations above 7,000 ft., please refer to your Goodman distributor for required kit(s).