6 www.goodmanmfg.com SS-GMV95
PRODUCT SPECIFICATIONS
GMV95 HIGH- OR SINGLE-STAGE COOLING SPEEDS
GMV95 LOW-STAGE COOLING SPEEDS
GMV950453BXB GMV950704CXB GMV950905DXB GMV951155DXB
Cooling
Speed Tap
Adjust
Tap
CFM¹
Cooling
Speed Tap
Adjust
Tap
CFM¹
Cooling
Speed Tap
Adjust
Tap
CFM¹
Cooling
Speed Tap
Adjust
Tap
CFM¹
A
Minus (-) 540
A
Minus (-) 540
A
Minus (-) 720
A
Minus (-) 720
Normal 600 Normal 600 Normal 800 Normal 800
Plus (+) 660 Plus (+) 660 Plus (+) 880 Plus (+) 880
B
Minus (-) 720
B
Minus (-) 720
B
Minus (-) 990
B
Minus (-) 990
Normal 800 Normal 800 Normal 1,100 Normal 1,100
Plus (+) 880 Plus (+) 880 Plus (+) 1,210 Plus (+) 1,210
C
Minus (-) 900
C
Minus (-) 990
C
Minus (-) 1,260
C
Minus (-) 1,260
Normal 1,000 Normal 1,100 Normal 1,400 Normal 1,400
Plus (+) 1,100 Plus (+) 1,210 Plus (+) 1,540 Plus (+) 1,540
D
Minus (-) 1,080
D
Minus (-) 1,286
D
Minus (-) 1,620
D
Minus (-) 1,620
Normal 1,200 Normal 1,429 Normal 1,800 Normal 1,800
Plus (+) 1,320 Plus (+) 1,572 Plus (+) 1,980 Plus (+) 1,980
¹ @ .1” to .8” W.C. ESP
Notes:
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.
• Constant Fan mode is 50% of above values
GMV950453BXB GMV950704CXB GMV950905DXB GMV951155DXB
Cooling
Speed Tap
Adjust
Tap
CFM¹
Cooling
Speed Tap
Adjust
Tap
CFM¹
Cooling
Speed Tap
Adjust
Tap
CFM¹
Cooling
Speed
Tap
Adjust
Tap
CFM¹
A
Minus (-) 380*
A
Minus (-) 378*
A
Minus (-) 513*
A
Minus (-) 514*
Normal 390 Normal 390 Normal 520 Normal 520
Plus (+) 429 Plus (+) 429 Plus (+) 572 Plus (+) 572
B
Minus (-) 468
B
Minus (-) 468
B
Minus (-) 644
B
Minus (-) 644
Normal 520 Normal 520 Normal 715 Normal 715
Plus (+) 572 Plus (+) 572 Plus (+) 787 Plus (+) 787
C
Minus (-) 585
C
Minus (-) 644
C
Minus (-) 819
C
Minus (-) 819
Normal 650 Normal 715 Normal 910 Normal 910
Plus (+) 715 Plus (+) 787 Plus (+) 1,001 Plus (+) 1,001
D
Minus (-) 702
D
Minus (-) 836
D
Minus (-) 1,053
D
Minus (-) 1,053
Normal 780 Normal 929 Normal 1,170 Normal 1,170
Plus (+) 858 Plus (+) 1,022 Plus (+) 1,287 Plus (+) 1,287
¹ @ .1” to .8” W.C. ESP
Notes:
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.