Goodman Mfg GMV95/GCV9 Furnace User Manual


 
4 www.goodmanmfg.com SS-GMV95
PRODUCT SPECIFICATIONS
GMV95 DIMENSIONS
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
Position Sides Rear Front Bottom Flue Top
Up ow 0” 0” 3” C 0” 1”
Horizontal 6” 0” 3” C 0” 6”
C = If placed on combustible oor, the oor MUST be wood ONLY.
Notes:
For servicing or cleaning, a 24” front clearance is required.
Unit connections (electrical, ue and drain) may necessitate greater clearances than the minimum clearances listed above.
In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clear-
ances are greater.
Model A B C D E
GMV950453BXB 17½” 16” 13”12”13
GMV950704CXB 21” 19½” 16 16 17½”
GMV950905DXB 24½” 23” 20”19”20
GMV951155DXB 24½” 23” 20”19”20
Notes:
Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the ue outlet (required). Vent pipe must be
either 2” or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation
(1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.
Line voltage wiring can enter through the right or left side of the furnace. Low-voltage wiring can enter through the right or left side of
furnace.
Conversion kits for high-altitude natural gas operation are available. Contact your Goodman distributor or dealer for details.
Installer must supply following gas line ttings, according to which entrance is used:
Left—Two 90º elbows, one close nipple, straight pipe
Right—Straight pipe to reach gas valve
For bottom return: Failure to unfold anges may reduce air ow by up to 18%. This could result in performance and noise issues.