Security Pro 1000
24
System Access Alarm
The panel cover was opened while the system was armed. The system will call the cen-
tral monitoring station to report a tamper alarm.
Testing As an added safeguard, there are system tests you should do yourself on a regular basis.
It is recommended that you test your system weekly.
Testing Sensors
You can test sensors one at a time to make sure they are sending strong signals to the
panel. You should test the security system at least once a week.
¾
To perform the sensor test:
1. Open the panel Cover.
2. Enter the master access code.
3. Press the Test button once. The panel will announce Sensor Test.
4. Press the DONE button.
Note
The RF Electronic Thermo-
stat is automatically tested
when a sensor test begins.
The panel will announce,
Sensor XXX activated, sta-
tus is one, if the thermostat
is OK.
The panel will voice prompt you with a list of your programmed sensors that you need
to test. The panel will start with sensor 1 and announce Test sensor 1, sensor name.
When you trip a sensor and it communicates successfully it will be removed from the
list. You may trip the sensors in any order.
After all sensors have been successfully tested, the panel will announce Sensor test
complete, press DONE. Press DONE. The panel will announce Sensor test ok.
If any of the sensors did not test successfully and you want to terminate the test, press
DONE or Cancel. The panel will announce Sensor test canceled or failure. If a sensor
test fails, call your security dealer.
Use the following table to trip devices:
Clearing System Status
Press the SYSTEM STATUS button, listen to the status message, then disarm the
system to clear system status. If the trouble condition was a low system battery, per-
form a sensor test. The SYSTEM STATUS button should turn off if all trouble condi-
tions have been corrected.
Device Do This
Door/Window Sensor Open the secured door or window.
Freeze Sensor Apply ice to the sensor. Do not allow the sensor to get
wet.
Water Sensor Press a wet rag or wet finger over both of the round,
gold-plated terminals on the underside of the sensor.
Carbon Monoxide Sensor Unplug the CO Alarm. Plug it back in, then press the
TEST/RESET button until the unit beeps 8 times.
Glass Guard Sensor Tap the glass 3 or 4 inches (8 cm) from the sensor.
Motion Sensor Avoid the Motion Sensor’s view for 5 minutes, then
enter its view.
Rate-of-Rise Heat Detec-
tor
Rub your hands together until warm, then place one
hand on the detector for 30 seconds.