GE E4H Series Water System User Manual


 
8
1.5.3 Concentrate Flow Rate
Factory set as stated on serial number label
Concentrate Outlet: 1-inch FNPT
1.5.4 Typical Pure Water
Recovery: 50 - 75%
1.5.5 Final Operating Pressure
Minimum: 200 psig (13.8 barg)
Maximum: 235 psig (16.2 barg)
1.5.6 Pump
Multi-stage centrifugal, approximate primary operating pressure of 190 psig
(13.1 barg), excluding line pressure.
1.5.7 Reverse Osmosis Membrane Element Rejection
Osmo HR(PA)
Typical Ionic Rejection (TDS) 95 - 98%
Average Molecular Weight Cutoff* 150 MW*
* The Molecular Weight cutoff is based on the pore size of the membrane elements and the nature
(size/shape) of the organic molecule.