• Alarms included: low inlet pressure, high amp draw, high / low pH
1.5 Specifications for E-Series Machines
1.5.1 Feed Water Requirements
Table 1.1
Feed Water Requirements
1.5.2 Permeate (Product Water) Flow Rate
Stated on the serial number label (assumes no permeate back pressure,
2000 mg/L TDS maximum feed concentration, and rated temperature).
To estimate permeate output with back pressure, use the formula below:
Permeate Back Pressure: Maximum: 80 psig (5.5 barg)
Permeate Outlet: 1-inch FNPT
7
Temperature
Inlet Pressure
Chlorine
(continuous feed)
Operating pH
Pre-filter
Inlet Connections
35° - 77°F (2° - 25°C) Not to exceed
85°F (29°C) unless specifically
designed for higher temperatures
Minimum: 30 psig (2.1 barg)
Maximum: 60 psig (4.1 barg)
For Osmo HR(PA) membrane ele-
ments: 0 ppm
Soft water [less than 1 grain per gal-
lon: 3.0 - 10.0 (gpg) or 17 mg/L hard-
ness], acceptable pH: 5.5 - 6.0
5 micron HYTREX cartridge
(part number on machine label)
1.5-inch FNPT*
(Permeate Flow on Label) x [(Operating Pressure) - (Permeate Back Pressure)]
Operating Pressure
* FNPT: Female National Pipe Thread