GE Concord 4 Home Security System User Manual


 
Concord 4 Series Security Systems
32
The Viewing Event History mode will exit automatically after one minute of inactivity OR
when an alarm occurs.
The following table is a comprehensive list of displayed events and their associated details (parti-
tion, current arming level, zone, bus unit number, source and user). If details are displayed for an
event an X will appear in the table.
Partitions are displayed as P1 - P6, depending on which partition the event occurred.
Current Arming Level will display Lx, where x is the current arming level of the event.
Zone will display Zx, where x is the zone of the event.
Bus Unit Number will display Bx, where x is the unit number of the Bus device.
Source will display Sxxx, where xxx is the source number in the event (see table on source
numbers for more information).
User will display Uxxx, where xxx is user number in the event (see table on user numbers for
more information).
Event Display Partition
Current
Arming
Level
Zone
Bus Unit
Number
Source
1
User
2
AC Power Failure AC POWER FAILURE X
AC Power Restoral AC POWER RESTORAL X
Antenna Tamper RCVR TAMPER X X
Arming Level Change
3
ARM LEVEL CHANGE X X X
Auto Force Arm AUTO FORCE ARM X X X
Auto Phone Test AUTO PHONE TEST X
Auxiliary Panic AUXILIARY PANIC X X
Auxiliary Panic Cancelled AUXLRY CANCELLED X X
Bus Cover Tamper BUS TAMPER X X
Bus Failure BUS FAILURE X X
Closing Report CLOSING REPORT X X X X
CPU Back In Service BACK IN SERVICE X X
CPU Battery Restoral BATTERY RESTORED X
CPU Low Battery CPU LOW BATTERY X
Daylight Savings Time Adjust DAYLIGHT SAVINGS
Download Session Entry DOWNLOAD ENTRY
Download Session Exit DOWNLOAD EXIT
Duress Alarm DURESS X X
Event Buffer Viewing Entry EVENT VIEW ENTRY X X X
Event Buffer Viewing Exit EVENT VIEW EXIT X X X
Fire Panic FIRE PANIC X X
Fire Panic Cancelled FIRE CANCELLED X X
Force Arm FORCE ARM X X X
Installer Programming Entry INST PROG ENTRY X X X
Installer Programming Exit INST PROG EXIT X X X
Lost Event (buffer overflow) LOST EVENT
Main Unit Tamper MAIN UNIT TAMPER X
Memory Clear MEMORY CLEAR
Memory Failure MEMORY FAILURE
No Activity Alarm ACTIVITY ALARM X