Stovax Open Log Burning Convector Fireboxes Indoor Fireplace User Manual


 
6
4. LIGHTING THE APPLIANCE
4.1 For best results:
•Setdampercontrols,SeeDiagram6
PR8068
Open
Close
•Placefirelightersorpaperanddrykindlingwoodonthe
base of the firebox
•Lightthepaperorfirelighters,SeeDiagram7
•Addlargerpiecesofwood
Too many logs may smother the fire.
Do not load fuel above the log guard and the secondary
combustion inlets at the back of the firebox.
See Diagram 8
Secondary
Combustion
inlets
Log Guard
PR8069
5. RUNNING THE APPLIANCE
5.1 Burning Wood:
To burn wood it is required to fit a log box as listed:
Riva Open
Cassette
16" 22" 24" 26" 28"
Product Code Std
Product Code Low
8610/
8611
8604/
8605
8606/
8607
8608/
8609
8673
Holyrood Black 8627 8628 8629 8630
Holyrood Polished 8627P 8628P 8629P 8630P
Castle 8623 8624 8625
Portcullis 8678 8666 8667 8668 8669
Contemporary
log box
8706 8711 8721
•Woodburnsbestonabedofash
•Raketheembersevenlyoverthefirebedandopenthe
Damper control (Diagram 6) fully for a few minutes before
re-fuelling
5.2 Burn new logs at high output for a few minutes before
adjusting the Air Damper control if required. Refuel little
and often for clean, efficient burning.
5.3 Experience establishes settings to suit personal preferences.
5.4 Do not burn large amounts of fuel with the Air Damper
control closed for long periods of time. This reduces the
build up of tar and creosote in the appliance and flue
system.
5.5 When in use, burning the appliance at high output for a
short period also reduces tars and creosote.
5.6 Burning Solid fuel:
To burn smokeless fuels it is required to fit a multi-fuel kit/
cast basket as listed:
Phoenix
Cassette
Product Code Multi-fuel
kit code
Cast Basket
Code
16" 8610/8611 8705 8686
22" 8604/8605 8710 8687
24" 8606/8607
-
8687
26" 8608/8609 8720 8688
28" 8673
-
8688