Stovax Open Log Burning Convector Fireboxes Indoor Fireplace User Manual


 
SITE REQUIREMENTS
16
4. BUILDERS OPENING
To make installation easier make the opening larger than
the minimum requirements where possible.
B
A
FRONT
C
Appliance Dim A Dim B Dim C
16" 420 560 360
22" 570 620 360
24" 620 620 360
26" 670 620 360
28" 720 620 360
Appliance Dim A Dim B Dim C
16" 420 510 360
22" 570 560 360
24" 620 560 360
26" 670 560 360
Standard Height
Low Lintel
Many fireplace openings have a supporting lintel. Remove
the covering plaster to identify it's position before starting any
constructive work. Do not remove constructional lintels without
making provision to support the remaining structure of the
building.
The appliance must not form any part of the supporting
structure.
4.1 The chimney/flue must have a sealed connection to the
appliance flue spigot.
4.2 The structure of the builders opening will reach high
temperatures. Use insulating blockwork to reduce the heat
transfer to the external walls, in particular the area of the
chimney breast above the opening.
4.3 Take care when finishing the chimney breast and
surrounding area. The conducted and convected heat
emitted by the appliance could be high enough to crack
normal plaster. Use a high temperature plaster, or face
the area with a suitable high temperature plasterboard.
New plaster should be fully dried before the appliance is
used, or cracking could occur.
If you are in any doubt about your ability to produce a
safe opening contact your Stovax dealer for professional
advice.
5. FIRE SURROUND CLEARANCES
If the appliance is to be fitted with a fire surround, use
the minimum clearances, see Diagram below, between
any point of the appliance and any combustible material.
Stovax produce a selection of surrounds and details can be
obtained from your local supplier.
150mm
300mm
150mm
PR8105
5.1 We recommend you obtain expert advice before
proceeding with work of this nature.
5.2 Some finishes may discolour with heat and some lower
quality products may distort, or crack, when in use.
If stone / granite / marble or any other natural material
is used to construct the fire surround, or any part of it,
provision should be made for expansion and movement
of the parts due to heating and cooling.
If you are in any doubt about the installation
requirements, or suitablity of fire surrounds contact your
Stovax dealer.
5.3 All fire surrounds should be suitable for use with solid fuel
heating products.