Stovax Open Log Burning Convector Fireboxes Indoor Fireplace User Manual


 
LEGAL REQUIREMENTS
Before installation of this product please read these
instructions fully.
It is very important to understand the requirements of the national
Building Regulations* and standards**, along with any local
regulations and working practices that may apply. Should any
conflict occur between these instructions and these regulations
then the regulations must apply.
Your local Building Control Office can advise regarding the
requirements of the regulations.
The appliance must be fitted by a registered installer†, or approved
by your local building control officer.
Works must be carried out with care to meet the requirements of
Health and Safety and comply with the Health and Safety rules,
and any new regulations introduced during the lifetime of these
instructions. Particular attention should be drawn to:
•Handling: The appliance is heavy. Adequate facilities
must be available for loading, unloading and site handling.
•Fire Cement: Some fire cement is caustic and must not
come into contact with the skin. Protective gloves must be
worn. Wash hands thoroughly with plenty of water after
contact with skin.
•Asbestos: This appliance contains no asbestos. If there
is the possibility of disturbing any asbestos in the course of
installation seek specialist guidance and use appropriate
equipment.
•Metal Parts: Take care when installing or servicing the
appliance to avoid personal injury.
A faulty installation can cause danger to the inhabitants and
structure of the building.
For users of this appliance:
Your building insurance company may require you to inform them
that you have installed a new heating appliance. Check that your
cover is still valid after installing the appliance.
1. INSTALLING THE APPLIANCE
To make the fitting of the appliance easier, gain better access to
the flue connection and protect paintwork from damage. The base
plate may be removed on the appliance, Diagram 3.
1.1 To get the best output from the appliance the rear and side
must be well insulated, Diagram 1.
1
Additional insulation may be required if the recess sizes are
larger than shown.
1.2 Any non-combustible insulation will be acceptable such
as vermiculite or Perlite. Poor insulators, such as lime or
rubble, should only be used after a good insulator has been
installed around the firebox.
1.3 Decide whether the insulation is to be positioned before
or after the installation of the firebox (vermiculite can be
poured through the flue-ways into the recess after the
appliance has been installed).
• Lifttheapplianceintoposition,Diagram2
• Pushbackuntilthefireboxflangessitflatagainstthe
fireplace opening
2
Insulation
Infill
Plan
Firebox Flange
Fireplace
Opening
1.4 No fixing is required but if the front face of the opening is
rough, such as natural stone, it will be necessary to seal the
flanges using fire cement
1.5 Ensure the box sits squarely and does not rock in any
direction.
1.6 Install the base plate by sliding it over the side and rear
ledges, Diagram 3
INSTALLATION INSTRUCTIONS
19
In the U.K:
*•EnglandandWales–DocumentJ/Scotland-PartF,
Building Regulations, 1997 Technical Guidance Document
J Heat Producing Appliances (Republic of Ireland only)
**•Registeredbody:HETAS(GBonly)/INFO(Eire)