3.3 The pilot unit can now be removed by undoing the two
screws. See diagram 6.
3.7 Reassemble in reverse order, do not overtighten.
NOTE: SPECIAL CARE SHOULD BE TAKEN WHEN
REPLACING THE THERMOCOUPLE TO THE BACK OF
THE GAS VALVE TO ENSURE THAT THE SENOR WIRES
FOR THE GAZCO FLUE SURE SYSTEM ARE NOT
DISCONNECTED.
4.1 Gain access to the pilot assembly, see section 3 and
disconnect the ignition lead from the electrode.
4.2 Remove the front cover from the control valve, see diagram
7 and 8, disconnect the other end of the ignition lead from
the valve body, note the existing route of the ignition lead.
4.3 Replace with a new ignition lead following the same route
as the old one. Replace the valve cover and the pilot
assembly.
4.4 Check operation of the new ignition lead.
5.1 The piezo assembly used on this appliance is not
serviceable and is unlikely to fail.
SERVICING INSTRUCTIONS
REPLACING PARTS
7
8
4. IGNITION LEAD
5. PIEZO
AR1445
6
AR0915
AR0916