Stovax 5 Stove User Manual


 
should be allowed before trying to relight. Continued
operation of this safety device means that there may be a
serious problem with the flue system; a qualified gas
engineer should inspect this. DO NOT USE THE STOVE
UNTIL AN ENGINEER SAYS IT IS SAFE TO DO SO.
2.8 The Flue Sure System must not be tampered with. Use only
genuine Gazco replacement parts when servicing the system
- refer to servicing section on page 19.
3.1 Open the carton, remove the accessory carton and stove
unit. It will now be necessary to decide upon top or rear
flue exit. The stove is factory built for rear flue exit but it
may be changed to top exit by simply interchanging the flue
spigot and blanking plate located on the stove.
3.2 Position the stove ensuring all appropriate clearances are
observed. Using a pencil, mark the position of the holes in
the fixing brackets attached to the inside of the rear legs.
3.3 Remove the stove and drill the holes using a number 12
masonry drill. Push rawlplugs into the holes and insert the
woodscrews until the head is approximately 3mm proud of
the hearth. Place the stove in position so that the screw
heads located in the large part of the slot in the bracket,
push the stove back so that the screw heads engage fully
into the narrow part of the slot, tighten the screws if
desired.
3.4 Having run the gas supply to the stove, PURGE THE
SUPPLY PIPE, this is essential to expel any debris that may
block the gas controls. Connect the gas supply to the 8mm-
compression elbow at the RH rear corner of the stove.
There is a cutout in the RH rear leg to enable a direct
straight connection to be made to the rear of the stove. See
diagram 3. A gas soundness check must be completed up to
the gas inlet connection.
10
IMPORTANT: ENSURE THAT THE APPLIANCE IS
CORRECTLY ADJUSTED FOR THE GAS TYPE AND
CATEGORY APPLICABLE IN THE COUNTRY OF USE.
REFER TO DATABADGE AND TECHNICAL
SPECIFICATIONS AT THE FRONT OF THIS BOOKLET.
FOR DETAILS OF CHANGING BETWEEN GAS TYPES
REFER TO SECTION 11 PAGE 20.
1.1 This stove is fitted with a control valve that can be easily
upgraded to battery powered remote control. There are two
versions of this control which can be obtained through your
local Gazco stockist.
1.2 This upgrade can be fitted before or after installation but if
side clearances are limited then it will be easier to upgrade
the stove before installation. Full instructions are included
with the kit.
1.3 STANDARD REMOTE CONTROL This remote control can
control the gas appliance after the pilot has been lit. It can
turn the main burner on and regulate it from low through to
high and back again. It can turn the main burner off leaving
the pilot burning. GAZCO PART NUMBER 8455.
1.4 THERMOSTATIC AND TIMER REMOTE CONTROL This
remote control can control the gas appliance after the pilot
has been lit. In ‘MANUAL MODE’ it can be used to turn
the main burner on and manually regulate it from low
through to high and back again. It can also be used to turn
the main burner off leaving the pilot burning. In ‘AUTO
MODE’ it will automatically regulate the room temperature.
In ‘TIMER MODE’ it will turn the fire on and off according
to a pre-set programme and automatically regulate the
room temperature during two on periods. GAZCO PART
NUMBER 8456
2.1 This appliance must be installed in accordance with the
rules in force, and used only in a sufficiently ventilated
space. Place read these instructions before installation and
use of this appliance.
2.2 All the instructions must be left intact with the user.
2.3 In your own interest, and those of safety, this appliance
must be installed by a competent person in accordance
with local and national codes of practice. Failure to install
the appliance correctly could lead to prosecution.
2.4 This appliance is intended for use on a governed gas
installation and set to the required pressure.
2.5 Keep all plastic bags away from young children.
2.6 Do not place any object on or near to the stove. Allow
adequate clearance above the stove. See diagram 2 page 9.
2.7 The stove is fitted with the Gazco Flue Sure System, which
will act to cut off the gas supply to the appliance in the
event of incorrect operation of the flue. If the system acts to
shut off the gas supply, this indicates that there is
insufficient flue pull. If this occurs a minimum of 10 minutes
INSTALLATION INSTRUCTIONS
INSTALLATION
1. CONTROL UPGRADE
2. SAFETY PRECAUTIONS
3. INSTALLATION OF THE STOVE
3
AR0934