COMMISSIONING
1.1 Close all openable doors and windows in the room, ignite
the stove and operate on maximum for 10 minutes.
Remove the plastic sight plug from the right hand side of
the stove. Position a lighted smoke match just inside the
draught diverter opening and check that all smoke is drawn
into the opening by viewing through the sight hole. See
diagram 1. If there is any doubt, run the stove for a further
10 minutes, and repeat the test.
1.2 If there are any extractor fans in adjacent rooms, the test
must be repeated with the fans running on maximum and
interconnecting doors open.
IF SPILLAGE PERSISTS, DISCONNECT THE APPLIANCE
AND SEEK EXPERT ADVICE.
For future reference record the installation details on the
commissioning sheet page 3 of these instructions.
1. COMMISSIONING
1