Stovax 8050 Indoor Fireplace User Manual


 
4
USER INSTRUCTIONS
2.3 • Holdinfor5to10secondsandthenrelease
The pilot remains lit. If the pilot does not light, repeat the
procedure.
2
AR0396
2.4 If the pilot still does not light after repeated attempts:
• Contacttheretailerorinstallerfromwhomtheappliance
was purchased.
• Lighttheappliancebymatchasatemporarymeasure,
see Section 4.
2.5 The appliance can now be turned to the high position to
ignite the main burner (
), then controlled between high
and low as desired.
THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE
HAS GAINED SUFFICIENT HEAT - TYPICALLY 10 TO 20
MINUTES.
IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN
USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO
RE-LIGHT THE APPLIANCE.
3. TURNING THE STOVE OFF
3.1 • Holdinthecontrolknobandturnclockwiseuntilthe
knob is pointing at the off position (
).
4. LIGHTING THE STOVE WITH A MATCH
4.1 • Slackenthedomednutontheupperdoorandloosen
the bolt from behind the latch
The door can now be opened.
1. GENERAL
1.1 A competent person must carry out installation and
servicing.
1.2 In all correspondence, please quote the appliance type and
serial number, which can be found on the databadge
located on a plate under the control valve.
1.3 Ensure that curtains are not positioned above the appliance
and there is at least 300mm between the sides of the
appliance and any curtains.
1.4 If any cracks appear in the glass panel do not use the
appliance until the panel has been replaced.
1.5 If, for any reason, the flue has to be removed from the
appliance, the seals must be replaced in the inner spigot.
1.7 Do not use a garden sprinkler or hose near the terminal.
1.8 Do not stand or place objects on the terminal guard as this
will deform it.
1.9 This product is guaranteed for 2 years from the date of
installation, as set out in the terms and conditions of sale
between Gazco and your local Gazco dealer. Please consult
with your local Gazco dealer if you have any questions. In
all correspondence always quote the Model Number and
Serial Number.
1.10 Any combustible shelves or surrounding furniture must only
be fitted in accordance with the minimum dimensions
detailed in diagram 1.
1
AR0887
2. LIGHTING THE APPLIANCE
2.1 • Ensurethecontrolispointingtotheoffposition(( )
Arrow A, Diagram 2).
2.2 • Holdinthecontrolknobandrotateanti-clockwiseuntila
click is heard and the knob is pointing at the ignition
symbol (( )Arrow B), the pilot should now be lit. See
diagram 2.