Stovax 8050 Indoor Fireplace User Manual


 
18
8. PRIMARY AERATION PLATE
8.1 • Turnthegassupplyoffattheisolationdevice.
8.2 To open the doors:
• Slackenthedomednutontheupperdoorandloosen
the bolt from behind the latch
8.3 • Removethetwoscrewssecuringthepilotunitandundo
the injector nut, Diagam 6,B
AR0895
6
• Removethefourfixingscrewsandwithdrawtheburner
unit, Diagram 6,C
8.4 Theaerationplateislocatedontherearoftheventuri:•
• Removethefixingscrewandreplacewiththecorrect
plate
When replacing the plate:
• Ensuretheloweredgeishookedovertheflangeofthe
venturi., Diagram 7,
AR0766
7
8.5 • Replacetheburner,ceramiccomponentsandcheckfor
leaks
• Closethedoorsandlocktheboltsandnuts
9. CHANGING BETWEEN GAS TYPES
In order to change between gas types, it will be necessary to
change the following items:
Burner Unit
Pilot Unit
Control Valve
Injector
Aeration Plate
Databadge
The relevant parts can be ordered from the parts list, always
quote the appliance type and serial number when ordering
spare parts.
*NOTE: THE CONTROL VALVE IS FACTORY PRESET FOR
CORRECT GAS TYPE AND MODEL, A NEW UNIT WILL
NEED TO BE ORDERED WHEN CHANGING BETWEEN
GAS TYPES.
10. SHORT SPAES LIST
APPLIANCE 8050 P8050
NG LPG
COMPONENT
BURNER UNIT
GZ3279 GZ3278
PILOT UNIT PI0047 PI0048
INJECTOR
IN0001 IN0003
AERATION PLATE
G20
GZ3269(C)
G30 N/A
G25
GZ3270(D)
G31
GZ2003(A)
GAS VALVE
GC0056*
FLUE SENSOR
EL0001
SENSOR LEAD
EL0064
INTERRUPTOR
GC0026
MAG UNIT
GC0016
PIEZO/IGN. UNIT
GC0062
GAS FILTER
GC0065
BURNER COVER
CE0358 CE0359
REAR PANEL
CE0357
FUEL BED
CE0356
COAL SET
CE0284
DATA BADGE
PR0397
SERVICING INSTRUCTIONS
REPLACING PARTS