Frymaster Pro H55-Series Burner User Manual


 
2-8
Non-CE Standard
Burner Manifold Gas Pressures
Gas Pressure
Natural
3" W.C.
0.73 kPa
Propane
8.25" W.C.
2.5 kPa
5. Check the programmed temperature or solid-state (analog) controller thermostat setting. (Refer
to the separate Frymaster Fryer Controllers User’s Manual furnished with your unit for the
setpoint programming instructions for your particular controller.)
2.5 Converting to Another Gas Type
DANGER
This appliance was configured at the factory for a specific type of gas. Converting
from one type of gas to another requires the installation of specific gas-conversion
components.
Switching to a different type of gas without installing the proper conversion
components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A
GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!
Conversion of this appliance from one type of gas to another should only be
performed by qualified, licensed, and authorized installation or service personnel, as
defined in Section 1.7 of this manual.
Pro H55 Series gas fryers manufactured for Non-CE countries use different burners for each type
gas. The burners in fryers built for Propane gas have a special gray-colored coating on the burner
tiles to enable them to withstand the higher caloric value of the Propane gas. Burners designed for
use in Propane units may be used in natural gas applications, but not vice versa.
Non-CE Gas Conversion Kits
Natural Gas to Propane (LP) Gas Propane (LP) Gas to Natural Gas
Full Vat: Part Number 826-1145 Full Vat: Part Number 826-1146
Dual Vat: Part Number 826-1147 Dual Vat: Part Number 826-1148
Units manufactured for export to CE countries are equipped with “universal” burners that may be
used with either Natural (G20, G25) gas or Butane (G30) and Propane (G31) gasses.
CE Gas Conversion Kits for Units with Gas Valve 810-1011
G20 or G25 (Natural) to G30 or G31 Gas: G30 or G31 to G20 or G25 (Natural) Gas:
Part Number 826-1196 Part Number 826-1197