Frymaster Pro H55-Series Burner User Manual


 
2-6
Gas Connection Pipe Sizes
(Minimum incoming pipe size should be 1 1/2" (41 mm))
Natural
3/4" (22 mm)
1" (28 mm) 1 1/4" (36 mm)
Propane 1/2" (15 mm) 3/4" (22 mm) 1" (28 mm)
Manufactured 1" (28 mm) 1 1/4" (36 mm) 1 1/2" (41 mm)
Gas Single Unit 2 - 3 Units
4 or more
units*
* For distances of more than 20 feet (6 m) and/or more
than 4 fittings or elbows, increase the connection by one
pipe size.
The Pro H55 Series gas fryer has received the CE mark for the countries and gas categories
indicated in the table below. NOTE: The nominal heat input (QN) is 21kW except for AT, DE, LU
and category 3P/B, which is 23kW.
COUNTRIES CATEGORIES GAS PRESSURE (MBAR)
G20 20
AUSTRIA (AT) II2H3B/P
G30, G31 50
I2E(R)B G20, G25 20, 25
BELGIUM (BE)
I3+ G30, G31 28-30, 37
G20 20
DENMARK (DK) II2H3B/P
G30, G31 30
G20, G25 20, 25
II2Esi3+
G30, G31 28-30, 37
G20, G25 20, 25
FRANCE (FR)
II2Esi3P
G31 50
G20 20
FINLAND (FI) II2H3B/P
G30, G31 30
G20, G25 20
II2ELL3B/P
G30, G31 50
GERMANY (DE)
I3P G31 50
G20 20
GREECE (GR) II2H3+
G30, G31 28-30, 37
G20 20
ITALY (IT) II2H3+
G30, G31 28-30, 37
G20 20
IRELAND (IE) II2H3+
G30, G31 28-30, 37
G20 20
LUXEMBOURG (LU) II2E3B/P
G30, G31 50
G25 25
II2L3P
G31 50
G25 25
NETHERLANDS (NL)
II2L3B/P
G30, G31 30
NORWAY (NO) I3B/P G30, G31 30
G20 20
PORTUGAL (PT) II2H3+
G30, G31 28-30, 37
G20 20
II2H3+
G30, G31 28-30, 37
G20 20
SPAIN (ES)
II2H3P
G31 37, 50
G20 20
SWEDEN (SE) II2H3B/P
G30, G31 30
G20 20
UNITED KINGDOM (UK) II2H3+
G30, G31 28-30, 37
CE Standard
Required airflow for the combustion air supply is 2m
3
/h per kW.
CE Approved Gas Categories by Country