Friedrich SS15N30* Air Conditioner User Manual


 
29
Remove the decorative front cover by using the tool
provided (see gure below).
Tighten the four (4) captive screws as indicated by the
arrows in the gure above before closing the front panel
(do not over tighten). Ensure the lter is in place.
Make sure curtains do not block the side air intake
Notes on reattaching the decorative front cover:
Align the cord notch over the cord and center the fresh
air lever. Align the cover over the User Interface
(UI) to ensure it is clear around it and it does not
depress any buttons. If not installed correctly the
wrench alert symbol could ash.
Remove the decorative front cover. (See gure at
left). Remove the chassis Entrygard Retainer Wire by
removing the screw at the front right bottom corner
(See Figure below). Save this screw for reattachment
after reinstalling the chassis.
Hold the cabinet stationary then use the hand grips on
both ends of the control unit support bracket to pull the
chassis out of the cabinet (see below).
Before reinserting the chassis into the sleeve ensure to
properly reinstall the chassis seal gasket.
REMOVING THE FRONT COVER
REMOVING THE CHASSIS
ELECTRIC SHOCK HAZARD
WARNING
Disconnect power to the unit before
servicing. Failure to follow this warning
could result in serious injury or death.
ELECTRIC SHOCK HAZARD
WARNING
Disconnect power to the unit before
servicing. Failure to follow this warning
could result in serious injury or death.