www.fmiproducts.com
111099-01L6
Figure 6 - Lineal Gain
LINEAL GAIN
PART NO. DESCRIPTION GAIN
42" Fireplace 44
"
12-8DM
12-8HT
PipeSection 10
5
/
8
"
18-8DM
18-8HT
PipeSection 16
5
/
8
"
24-8DM
24-8HT
PipeSection 23
5
/
8
"
36-8DM
36-8HT
PipeSection 34
5
/
8
"
48-8DM
48-8HT
PipeSection 46
5
/
8
"
RT-8DM RoundTermination 6
7
/
8
"
*
RTL-8DM RoundTermination 7
3
/
4
"
*
RTT-8DM
RoundTermination
withSlipSection
6
7
/
8
" to
23
1
/
8
"*
RTTL-8DM
RoundTermination
withSlipSection
8
1
/
2
" to
21
1
/
2
"*
ET-8DM SquareChase-Top 12
"
*
ETO-8DM
SquareChase-Top
withMesh
12
"
*
ETL-8DM
SquareChase-Top
withSlipSection
7"to15"*
ETLO-8DM
SquareChase-Top
withMesh&Slip
Section
12
"
to
25
1
/
2
"
*
*Thelinealgainfortheterminationsismea-
suredtotheuegasoutletheight.
Hemmed
End
8"Stainless
InnerPipe
12
3
/
8
"Galvanized
OuterPipe
ASSEMBLY AND INSTALLATION OF
DOUBLE WALL CHIMNEY SYSTEM
Each double wall chimney section consists of
agalvanizedouterpipe,astainlesssteelinner
uepipeandawirespacer.Pipesectionsmust
be assembled independently as the chimney
isinstalled.Whenconnectingchimneydirectly
toreplace,theinneruepipesectionmustbe
installedrstwithlancedsideup.Theouter
pipesectioncanthenbeinstalledovertheue
pipesectionwithhemmedendup.Pressdown
on each pipe section until lances securely
engagehemonreplacestarter.Thewirewill
assure the proper spacing between inner and
outer pipe sections.
VENTING INSTALLATION
OPTIONAL OUTSIDE AIR KIT
(MODEL AK4/AK4F)
Theinstallationofanoutsideairkitshould
be performed during the rough framing of
thereplaceduetothenatureofit'slocation.
Outsidecombustionairisaccessedthrough
aventedcrawlspace(AK4F)orthrougha
sidewall (AK4).
CAUTION: Combustion air
inlet ducts shall not terminate
in attic space.
Figure 5 - Outside Air Kit
SecuretoCollarswithMetalTape,
ScrewsorStraps(Min.of1/4"x20"
insize)
AirInlet
Location
MustAllow
ForBushes
orSnow
VentHood
Requiredfor
WallInstallation
AirInlet
Eyebrow
VentedCrawlSpace
(CheckLocalCodes
BeforeInstallingina
VentedCrawlSpace)
CHIMNEY PIPE
TheFMIPRODUCTS,LLCchimneysystem
consistsof12",18",24",36"and48"snap-
lock, double-wall pipe segments, planned
for maximum adaptability to individual site
requirements.Actuallengthsgainedaftert-
ting overlaps must be taken into consideration
(lineal gain) and are given in the lineal gain
chart(seeFigure6).Linealgainistheactual
measurable length of a part after two or more
partsareconnected.ForCanada,usechimney
partsdesignated"HT".
WARNING: The opening in
the collar around the chimney at
the top of the replace must not
be obstructed. Never use blown
insulation to ll the chimney
enclosure.