www.fmiproducts.com
111099-01L 11
OPTIONAL GAS LINE INSTALLATION
Figure 19 - Gas Line Knockout
Side
Firebrick
Finished
Side
Refractory
Knockout
Plug
Outsideof
Fireplace
GasLine
Conduit
Insulation
Gas
Conduit
Cover
1/2"Dowel
(seeFigure20,page12).Note: Secure
incoming gas line to wood framing to
provide rigidity for threaded end.
4. Repackinsulationaroundgaslineandinto
sleeveopening.Sealanygapsbetween
gas line and refractory knockout hole with
refractory cement or commercial furnace
cement,Installthegasapplianceorcap-
off gas line if desired.
VENTING INSTALLATION
Continued
30E-8DM
EFFECTIVE HEIGHT
OF TERMINATION CAP
EFFECTIVE HEIGHT
OF TERMINATION CAP
EFFECTIVE HEIGHT
OF TERMINATION CAP
EFFECTIVE HEIGHT
OF TERMINATION CAP
MINIMUM
HEIGHT
14.5 FT.
MINIMUM
UP TO
6FT. MAX.
UP TO
6FT. MAX.
HEIGHT
14.5 FT.
MIN. HEIGHT
OF 22 FT. (WITH
2 ELBOW SETS)
MAX. HEIGHT OF
50 FT.
MAX. HEIGHT
50 FT.
(ANY SYSTEM)
30E-8DM
Figure 18 - Typical Residential Installations
Gaslinehookupshouldbedonebyyour
supplieroraqualiedserviceperson.
Note: Before you proceed, make sure your
gas supply is turned off.
Useonlya1/2"blackironpipeandappropri-
atettings.
1. Removeknockoutindentationonrefrac-
toryorrebrickwalllocatedabovethe
refractoryhearthfloor.Theknockout
indentationmustbermlytappedwithany
solid object such as a 1/2" dowel until it is
released.Removefragmentedportionsof
refractory(seeFigure19).
2. Removegaslinecoverplatelocatedon
eithersideofreplaceandpulloutinsu-
lationfromgaslineconduitsleeve.Save
insulationforreuse.Replacescrews.
3. Runa1/2"blackirongaslineintothe
fireplace through the rear at gas line
conduit sleeve (if using a raised platform,
addheight).Providesufcientgaslineinto
replacechamberforttingconnection