FMI MM44 Indoor Fireplace User Manual


 
www.fmiproducts.com
125160-01A30
FIREPLACE GRATES
To complete your replace installation, a replace
grate will be required for safe operation. The replace
grate can be obtained from FMI PRODUCTS, LLC
(see Accessories on page 33) or if choosing an alter-
nate, it must be sized to 50% of the hearth maximum.
Additionally. A replace screen must be installed for
safety.
SCREENS
GLASS DOORS
IMPORTANT: Only Crown-Breckinridge or
McKenzie-Pendelton Doors by Portland-Willamette
(www.portwill.com) are approved for use with this
replace.
For installation Instructions, see separate instruc-
tions included with doors.
Glass doors are optional with the replace. When
replace is in operation, doors must be fully opened
or fully closed position only or a re hazard may be
created (see Figure 49).
A replace equipped with glass doors operates much
differently than a replace with an open front. A re-
place with glass doors has a limited amount of air for
combustion.
Excessive heat within the replace can result if too
large a re is built or if combustion air gate is not
completely open. The following tips should be fol-
lowed to assure that both the replace and glass door
retain their beauty and function properly. Both the ue
damper and glass doors must be fully opened before
starting re. This will provide sufcient combustion air
and maintain safe temperatures in rebox.
IMPORTANT: The glass must be allowed to warm
slowly and evenly. The tempered glass will withstand a
gradual temperature rise to 375 °F, without sustaining
any damage. Termperatures as high as this or higher
are not likely to occur with normal use. Such materials
as pitch/wax laden logs, very dry mill end lumber and
large amounts of paper or cardboard boxes can create
an excessively hot re and should not be burned in
this replace. Always keep the re well back from the
doors and never allow ames to contact the glass.
Figure 49 - Bi-Fold Glass Doors
Doors Fully Closed
Fireplace Front
Doors
Fully Opened
Fireplace Front
OPERATION AND MAINTENANCE GUIDLINES
WARNING: Fireplaces equipped with glass
doors should be operated only with doors fully
opened or doors fully closed. Doors, if left partly
open, may draw gas and ame out of the replace
opening creating risks of both re and smoke.
Cleaning Glass
Clean glass with any commercial glass cleaner or
soap and water. Do not use any abrasive material to
clean glass. Do not clean glass with any cool water if
glass is still hot from the re and smoke.
OWNER’S OPERATION & PRECAUTIONS
WARNING: Do not attempt to operate your
replace without a re safety screen installed.
CAUTION: The manufacturer cautions
against using chemical chimney cleaners. Never
use charcoal or coal in the replace under any
circumstances.
First Lighting of the Grand Meridian – After con-
struction is completed, all elements of the re-
place and chimney system must be complete-
ly dry. This means that the unit must stand
without any ring for a minimum of 28 days.
Only after that period of time can a rst lighting take
place. The rst re must be small and well-controlled,
started with a small amount of kindling. Add no more
than eight pounds of wood, preferably small logs
not more than 3” (three inches) in diameter. You will
probably burn no more than three to four of these
small logs. Do not let the re burn for more than one
hour. After this rst lighting – when the replace has
started to “cure” Do not set another re for at least
24 hours.