CLEANING AND MAINTENANCE
Continued
TROUBLESHOOTING
        


 

Note: All troubleshooting items are listed in order of operation.

1. Ignitor electrode not con-
nected to ignitor cable
2. Ignitor cable pinched or
wet
3. Broken ignitor cable
4. Bad ignitor
5. Ignitor electrode posi-
tioned wrong
6. Ignitor electrode broken
7. Battery not installed, bat-
tery power low or battery
not installed correctly
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched
by any metal or tubing.
Keep ignitor cable dry
3. Replace ignitor cable
4. Replace ignitor
5. Replace pilot assembly
6. Replace pilot assembly
7. Install new alkaline battery
in electronic ignitor. Verify
battery is installed cor-
rectly

When ignitor button is pressed,
there is no spark at ODS/pi-
lot
LOG SET
If you remove one-piece log set for clean-
ing, refer to Installing Log Set and Screen,
page 18, for placement instructions.
Replace log set if broken or chipped (dime-
sized or larger).
CABINET

Use pressurized air to clean.
Exterior
Use a soft cloth dampened with a mild soap
and water mixture. Wipe the cabinet to remove
dust.