FMI CGMFP Indoor Fireplace User Manual


 
www.fmiproducts.com
119315-01D 15
INSTALLATION
Continued


and connections, internal and
external to unit, for leaks after




a noncorrosive leak detection
-


CAUTION: Make sure exter-

  
   
under Connecting to Gas Sup-
ply




1. Disconnect appliance with its appliance
main gas valve (control valve) and equip-
ment shutoff valve from gas supply piping
system. Pressures in excess of 1/2 psig
will damage heater regulator.
2. Cap off open end of gas pipe where equip-
ment shutoff valve was connected.
3. Pressurize supply piping system by either
opening propane/LP supply tank valve
for propane/LP gas or opening main gas
valve located on or near gas meter for
natural gas or using compressed air.
4. Check all joints of gas supply piping system.
Apply noncorrosive leak detection uid to
all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Reconnect fireplace and equipment
shutoff valve to gas supply. Check recon-
nected ttings for leaks.


1. Close equipment shutoff valve (see Fig-
ure 16).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve
for propane/LP gas or opening main gas
valve located on or near gas meter for
natural gas or using compressed air.
3. Check all joints from gas meter to equip-
ment shutoff valve for natural gas or pro-
pane/LP supply to equipment shutoff valve
for propane/LP (see Figures 17 or 18).
Apply noncorrosive leak detection uid to
all joints. Bubbles forming show a leak.
4. Correct all leaks at once.
Figure 16 - Equipment Shutoff Valve
Open
Closed
Equipment
Shutoff Valve
Figure 17 - Checking Gas Joints
(Propane/LP Only)
Propane/LP
Supply Tank
Equipment
Shutoff Valve
Gas Valve
Equipment
Shutoff Valve
Gas
Meter
Figure 18 - Checking Gas Joints (Natural
Gas Only)
Gas Regulator or
Gas Control Valve