FMI CGMFP Indoor Fireplace User Manual


 
www.fmiproducts.com
119315-01D10
INSTALLATION
Continued

WARNING: Maintain the
minimum clearances shown

   

    -
    

  -

-

    

If your replace is to be used with an optional
mantel, the installation instructions included
with your mantel shows an CSA approved
method of attaching the replace/mantel sys-
tem to a wall. IMPORTANT: Only use optional
cabinet or corner mantels specied in this
manual. Purchase the optional mantel from
your dealer (see Accessories, page 34).
If your replace is to be recessed into the wall,
see Built-In Fireplace Installation to secure
your replace into the wall.
CAUTION: If you install the

 

 

For convenience and efciency, install re-
place
where there is easy access for operation,
inspection and service
in coldest part of room


A. Clearances from the side of the replace
cabinet to any combustible material and
wall should follow diagram in Figure 6.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/
2
" from the wall. This com-
bustible material must be 4" from the side
of the replace opening (see Figure 6).
B.
Clearances from the top of the replace
opening to the ceiling should not be less
than 36".
C. For mantel clearances, see Figure 9 on
page 12.
Figure 6 - Minimum Clearance for
Combustible to Wall
*Minimum 16" from Side Wall
*
Example
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS

Left and

Bottom and
Rear
Front
36" 6" 0" 36"

Built-in installation of this replace involves
installing replace into a framed-in enclosure.
This makes the front of replace ush with
wall. Fireplace face will extend past sides
and top of replace approximately 1". This will
cover the rough edges of the wall opening. If
installing a built-in mantel above the replace,
you must follow the clearances shown in Fig-
ure 9, page 12. To install the replace in this
manner, use the following instructions.