Excalibur electronic P95-NG3 Indoor Fireplace User Manual


 
Excalibur
®
P95-3 Zero Clearance Direct Vent Gas Fireplace
32
WIRING DIAGRAMS
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
This heater does not require a 120V A.C. supply
for operation. In case of a power failure, the
burner switch and the optional remote control/
thermostat will continue to operate. However,
a 120V A.C. power supply is needed for the
fan/blower operation.
(Do not cut the ground terminal off under
any circumstances.)
NOTE: Even if the fan is not purchased
with the unit, it is still a good idea to
bring power to the receptacle box
(provided with the unit) in case the
fan is installed at a later date.
CAUTION: Label all wires
prior to disconnection when
servicing controls. Wiring
errors can cause improper and
dangerous operation.
INSTALLATION
Ground
Green
Neutral
Live
Black Red Red
Fan Thermodisc
(normally open)
Ground
ON OFF
Rotary Speed
Control
120VAC
60 Hz
FanA
Fan B
Lockwasher
Fan
ground wire
Power cord
ground wire
Nut
#8 Ground Lug
(for mobile home)
Star
washer
Piezo
Ignitor
To Thermocouple IN
Pilot
Assembly
H
I
L
O
O
F
F
O
N
P
I
L
O
T
Gas Pilot
Thermopile
Thermocouple
Electrode
Remote Transmitter
(Optional)
ON OFF
Regency
Remote Receiver
or Thermostat
(Millivolt) (Optional)
Brown
Red
T-Stat
Black
White
"S.I.T" Valve
Burner
ON
OFF
Thermostat
(To THTP)
(To TH)
White
Gas
In
For NATURAL GAS Units and Units NOT Equipped with DC Spark Boxes