Envision Peripherals Geothermal Indoor Split Heat Pumps Heat Pump User Manual


 
2
ENVISION SERIES INSTALLATION MANUAL
Model Nomenclature
N D Z 049 A 1 1 A C
Coax Options
Model Type C= Copper
N= Envision N= Cupronickel
Compressor Type Open Option
D= Dual Capacity A= Standard
S= Single Speed
Hot Water Option
Cabinet Configuration 0= None
Z= Indoor Split 1= Hot Water Gerneration with
factory installed pump
Unit Capacity
Voltage
Vintage 1= 208-230/60/1
A= Current
Physical Characteristics
Model 022 030 036 042 048 060 070 026 038 049 064 072
Compressor (1 each)
Factory Charge R410a, oz [kg]
56
[1.59]
56
[1.59]
56
[1.59]
74
[2.1]
90
[2.55]
92
[2.61]
108
[3.06]
52
[1.47]
56
[1.59]
90
[2.55]
92
[2.61]
104
[2.95]
Coax and Water Piping
Water Connections Size - Swivel- in [mm]
1 [25.4]
HWG Connection Size - Swivel - in [mm]
1 [25.4]
Coax & Piping Water Volume - gal [l]
0.7
[2.6]
1.0
[3.8]
1.3
[4.9]
1.3
[4.9]
1.6
[6.1]
1.6
[6.1]
2.3
[8.7]
0.7
[2.6]
1.3
[4.9]
1.6
[6.1]
1.6
[6.1]
2.3
[8.7]
Weight - Operating, lb [kg]
164
[74]
174
[79]
212
[96]
213
[97]
246
[112]
251
[114]
292
[132]
189
[186]
236
[107]
250
[113]
271
[123]
290
[132]
Weight - Packaged, lb [kg]
184
[83]
194
[88]
232
[105]
233
[106]
266
[121]
271
[123]
312
[142]
209
[95]
256
[116]
270
[122]
291
[132]
310
[141]
Notes:
All units have TXV expansion devices, and 1/2" [12.2mm] & 3/4" [19.1mm] electrical knockouts.
Rev.:6/7/07
1 [25.4]
Single Speed Scroll Dual Capacity Scroll
1 [25.4]