Enviro 50-1578 Stove User Manual


 
13
Installation
VERTICAL RISE WITH HORIZONTAL TERMINATION INSTALLATION (RECOMMENDED):
A 45° elbow with a rodent screen may be used
in place of the termination cap (or stainless
steel termination hood).
THROUGH CONCRETE WALL WITH VERTICAL RISE INSTALLATIONS:
A 45° down elbow with a rodent screen may
be used in place of the termination cap (or
stainless steel termination hood).
Installation to use if there is a concrete or
retaining wall in line with exhaust vent on pellet
stove.
The termination must be 305mm (12”) from
the outside wall and 305mm (12”) above the
ground.
Figure 12: Vertical rise with Horizontal Termination.
Figure 11: Through Wall with Horizontal Termination.
Wall framing
Wall thimble
Termination
cap
Vertical section
of vent pipe
Horizontal frame
for thimble
Clean out tee
90°elbow
 
Concrete
Wall
Wall framing
Wall thimble
Termination cap
Vertical section
of vent pipe
Clean out tee
 
Wall strap
90°elbow
Horizontal frame
for thimble