Enviro 50-1578 Stove User Manual


 
SLIDER/DAMPER SETTING:
THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION, IT IS USED TO REGULATE
THE AIRFLOW THROUGH THE PELLET STOVE.
A Qualified Service Technician or Installer must set the Slider Damper.
If the unit has been placed in the HI / LOW mode,
the unit will be taken to a low or idle setting when
the thermostat is not calling for heat. When the
thermostat calls for heat, the unit will go to the
setting that is displayed on the control board Heat
Indicator. If the heat in the room becomes to great,
the high limit switch may turn the stove off and
the switch will have to be manually reset. To reset
the high limit switch, remove the right cabinet
side. The switch is found behind the control panel.
Avoid setting off the high limit switch.
Installation
THERMOSTAT INSTALLATION:
1. Install the wall thermostat (12 or 24 Volt rated) in a location that is not to close too the unit but will
effectively heat the desired area.
2. Connect the Thermostat or Timer using an 2 x 18 gauge wire from the unit to the thermostat.
Remove jumper
wire and install
thermostat wires here.
Figure 21: Thermostat wire placement.
Figure 22: Slider / Damper
Note: Some parts have been removed in
order to see components more clearly.
Slider Damper Plate
Exhaust Channel
Exhaust Blower
The slider damper should
be set only on a hot stove
(operating for thirty (30)
minutes or more) by placing
a Magnahelic Pressure Gauge
in the firebox (test port is
located in the center of the
stove just below the door
opening). Set the slider
damper so that the pressure
reads 0.18” to 0.20” W.C.
(44.8 to 49.8 Pa). Some
fuels may require higher
or lower settings. The
pressure readings are taken
through a hole in the front
of the firebox under the door,
using a Magnehelic Gauge.
20