REPLACINGCOMPONENTS
ConvectionBlower
1. Beforebeginninganycomponent
replacement,becertaintheunitis
unpluggedandthoroughlycooled
down.
2. Removethebackexhaustoutlet
coverplateandbackpanelfromthe
unit.
3. Detachtheconvectionblowerfrom
thewiringharnessbeforeloosening
thefourscrewswhichsecureitto
theconvectionshroudofthestove.
4. Afterlooseningandremovingthe
fourscrewswhichholdtheblower
tothestove,removetheblower
fromthestove.
5. Installationofthenewbloweris
performedinreverseofremoval;
remembertoreconnectthenew
blowertothewiringharness.
CombustionBlower
1. Beforebeginninganycomponent
replacement,becertaintheunitis
unpluggedandthoroughlycooled
down.
2. Removethe5/16”screwwhich
holdstheexhaustbloweraccess
doortothestove.
3. Disconnecttheventingsystemfrom
theexhaustblower,anddisconnect
theexhaustblowerfromthestove
wiringharness.Removethethermal
sensorscrewonthetopofthe
exhaustbloweroutletusinga5/16”
wrench.
4. Removeallfivescrewswhichhold
theexhaustblowertotheexhaust
blowertube.Oncethescrewshave
beenremoved,theblowercanbe
liftedupandoutofthestove.
5. Reinstallationistheexactopposite
ofthestepsabove;howeverbe
certaintochecktheconditionofthe
exhaustblowergasketandreplaceif
necessary.
ConvectionBlower
CombustionBlower