Page | 13
INSTALLATION
MobileHomeInstallation
TheEngland’sStoveWorks,Inc.outsideairkitMUSTbeusedforinstallationofthisunitina
mobilehome.Pleaseseethe“OutsideAir”sectiononpage14formoreinformation
regardingoutsideairconnections.
Theoutsideairinletmustbekeptclearofleaves,iceandotherdebris.Keepingtheoutside
airinletfreeofrestrictioniscrucialtopreventingairstarvationandsmokespillage.
ThepelletstoveMUSTbesecuredtothefloorofthemobilehomeusinglagboltsandthe
holesprovidedinthebottomofthebaseforthispurpose.Outdoor‐aired
spaceheaters
mustbeattachedtothestructure.
ThepelletstoveMUSTbegroundedwith#8solidcoppergroundingwire(orequivalent),
terminatedateachendwithanNECapprovedgroundeddevice.
CarefullyfollowallclearanceslistedintheappropriatesectionofthismanualANDfollow
theventing
manufacturer’sminimumclearancerequirements.Similarly,becertainthe
ventingsystemusedisapprovedformobilehomeuse.
InstallationmustbeinaccordancewithManufacturersHome&SafetyStandard(HUD)CFR
3280,Part24aswellasanyapplicablelocalcodes.
Usesiliconetocreateaneffectivevaporbarrieratthelocationwherethechimneyor
outsideairductingpassesthroughtotheexteriorofthestructure.
WARNING:DONOTINSTALLINASLEEPINGROOM.
CAUTION
THESTRUCTURALINTEGRITYOFTHEMANUFACTUREDHOMEFLOOR,WALL
ANDCEILING/ROOFMUSTBEMAINTAINED.
DONOTCUTTHROUGHFLOORJOISTS,WALLSTUDS,CEILINGTRUSSESORANY
OTHERSUPPORTINGMATERIALWHICHCOULDBEDETRIMENTALTOTHE
STRUCTURALINTEGRITYOFTHEHOME.
JoistShield/Firestop
MobileHome
ApprovedTypePorPL
PelletVentPipe
RoofFlashingand
StormCollar
ChimneyCap/SparkArrestor
For high altitude installations (above 4,000 ft.), the vent pipe should be
increased from 3-inch
(
3”
)
to four-inch
(
4”
)
.