Empire Comfort Systems BVD36FP32 Indoor Fireplace User Manual


 
Page 719400-3-0406
Mantel Chart (Figure 3)
Figure 3
Clearances (Figure 4)
Clearance from top front edge of fireplace to ceiling is 36"
Clearance from side of fireplace to adjacent sidewall is 6".
Figure 4
Figure 5
Note: When you install your
Fireplace on wall corner
positions, a minimum of 6 inches
clearance must be maintained
from the perpendicular side wall
and the screened opening of the
appliance.
Figure 2
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.
Clearance to Combustibles
Back 0" (0 mm)
Side 0" (0 mm)
Floor 0" (0 mm)
Top Stand-off
0" (0 mm)
Top Framing Edge
1" (25mm)
12”
TO
PEDGEOFFIREPLACE
12”(305mm)
10”(254mm)
MANTEL
COMBUSTIBLETRIM
ANDMANTELS
ALLOWED
INSHADEDAREA
1/4”
(6.35mm)
3”
4”
5”
6”
8”
103/4”
3/4”
21
/4”
3”
33/4”
4½”
6”
8”
1”
2”
SEEMANTLE CHARTFOR
MAXIMUMMANTLE DEPTH
NAILING
FLANGES
GLASSFRONT
(OPTIONAL)
TO
PFRAMING
LEDGE
FINISHEDWALL
(COMBUSTIBLE)
SEEMANTLE CHART
FORMINIMUM HEIGHT
OFMANTLEABOVE UNIT
2"x 4"HEADER
STAND
OFF
3"(76 mm)HEIGHT
ABOVETOPO
F
FIREPLACE
CLEARANCES
LOCATING FIREPLACE